A new, simple, rapid, precise, accurate and reproducible RP-HPLC method for estimation of Lenalidomide in bulk form and marketed formulation. Separation of Lenalidomide was successfully achieved on a Symmetry ODS C18 (4.6 x 250mm, 5mm) column in an isocratic mode of separation utilizing Acetonitrile: Methanol in the ratio of 80:20% v/v at a flow rate of 1.0 mL/min and the detection was carried out at 272nm. The method was validated according to ICH guidelines for linearity, sensitivity, accuracy, precision, specificity and robustness. The response was found to be linear in the drug concentration range of 10-50mcg/mL for Lenalidomide.The correlation coefficient was found to be 0.999 for Lenalidomide. The LOD and LOQ for Lenalidomide were found to be 1.1µg/mL and 3.2µg/mL respectively. The proposed method was found to be good percentage recovery for Lenalidomide, which indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard solution with the sample solution. Therefore, the proposed method specifically determines the analyte in the sample without interference from excipients of pharmaceutical dosage forms.
KALEPU SWATHI , CHAITANYA MITTA , P.MANICHANDRIKA , FATIMA TASKEEN SIDDIQA , LATHA AGARWAL, AFIFA MOHAMMADI , MUHEEBA FATIMA, MALEEHA FATIMA
Lenalidomide, RP-HPLC, Accuracy, Precision, Robustness, ICH Guidelines.